Fire-resistant glass doors, three opening types
Summary for decision-makers
Fire-resistant glass doors: MAF Atlantique's innovative solution for fire safety in France
MAF Atlantique, the only French manufacturer to offer all three types of fire-resistant glass doors (sliding, hinged, and swing) under its own brand, is showcasing its expertise at the BATIMAT trade show. Thanks to its partnership with Record Portes Automatiques, the company offers a comprehensive, certified, and nationwide solution tailored to public buildings and commercial properties, combining fire safety, design, accessibility for people with reduced mobility, and centralized maintenance.
Sliding, hinged, or swing-out, fire-resistant glass doors must combine fire resistance, pedestrian access, and architectural constraints. At BATIMAT, MAF Atlantique is presenting three solutions covering these configurations, including two motorized models combined with a nationwide commissioning and maintenance service in partnership with Record Portes Automatiques.
Summary
- Three fire-resistant glass doors, as required.
- Motorization adds safety requirements
- Fire resistance and DAS (Diagnostic Adequacy Specifications) frame the design
- Commissioning and maintenance on a national scale
Good reading !
Three fire-resistant glass doors, as required.
The choice of a fire-resistant glass door depends in particular on the expected opening mechanism and the required level of fire resistance. For specifiers, architects, and project owners, this diversity should allow for the integration of fire protection while maintaining natural light and visibility between spaces.
MAF Atlantique is presenting three product lines developed by its R&D department at BATIMAT. Kronos is a motorized sliding door classified EI30, with configurations up to EI90 and E120. Cardéa 30 , a motorized swing door, is rated EI30, up to EI60 and EW60. Cybèle , a swing door, also boasts an EI30 rating, up to EI60 and EW60.
According to MAF Atlantique, the company is the only French manufacturer to master and market these three main configurations of fire-resistant glazed doors under its own brand . These developments complement the catalog of the systems supplier Jansen, which does not cover these specific configurations.
The range is aimed in particular at establishments open to the public , tertiary buildings and projects requiring a combination of fire compartmentation, architectural transparency and people circulation.
Motorization adds safety requirements
For a motorized fire door , the fire resistance of the door frame is only one part of the system. The motor, safety equipment, connections, and commissioning also contribute to the overall operation.
Kronos is thus equipped with the Drive STA20 Fire motor , while Cardéa 30 uses the DFA127 Fire operator from Record Automatic Doors. Safety equipment compliant with the EN 16005 standard has been validated by fire tests and included in the door test reports, according to MAF Atlantique.
The issue directly concerns pedestrian safety , including in the event of a fire. This constraint must therefore be taken into account from the initial design of the door and its automation system, and not only during installation.
Fire resistance and DAS (Diagnostic Adequacy Specifications) frame the design
Kronos and Cardéa motorized doors have been designed to incorporate several requirements cited by the manufacturer. MAF Atlantique specifically mentions the decree of March 22, 2004 relating to the fire resistance of construction products , the NF S 61-937 standards applicable to Safety Actuated Devices (DAS) and the EN 16005 standard relating to the safe use of motorized pedestrian doors.
The equipment must also meet the accessibility requirements for people with reduced mobility . NF277 certification complements the manufacturer's existing system for equipment conformity, quality, and performance.
For project owners, inspection bodies, and operators, these various elements mean that the door must be considered as a whole. MAF Atlantique thus identifies several links in the safety chain: fire resistance test report, fire safety inspection report, motorization, connections, commissioning, and installation monitoring.
Commissioning and maintenance on a national scale
A motorized security door must also remain operational after delivery. It is in this respect that MAF Atlantique relies on its partnership with Record Portes Automatiques , whose automation systems equip Kronos and Cardéa 30.
The proposed service covers the supply of doors and equipment , the connection of automation systems, commissioning, upkeep, and maintenance. The program is announced nationwide.
For project owners, specifiers, companies, and operators, the goal is to coordinate the work of the joinery manufacturer and the automation specialist. This continuity applies both to the initial equipment selection and its ongoing maintenance in operational condition.
“Our uniqueness lies not only in the breadth of our product range. It also stems from our ability to manage even the most unusual dimensions of a fire-resistant glass door project, from design to maintenance. Thanks to our partnership with Record Automatic Doors, we can offer a coordinated response nationwide.”
Guillaume Leborgne, director of MAF Atlantique
With the sliding, hinged, and swing configurations presented at BATIMAT, choosing a fire-resistant glazed door is not simply a matter of fire resistance rating. For motorized projects in particular, the consistency between the door frame, automation, safety devices, commissioning, and maintenance is a factor to consider from the initial specification stage.
Frequently Asked Questions
What are the main fire-resistant glass doors offered by MAF Atlantique?
MAF Atlantique offers three types of fire-resistant glass doors under its brand: sliding (Kronos), hinged (Cardéa 30) and swing (Cybèle), covering various architectural configurations.
What certifications guarantee the conformity of MAF Atlantique fire doors?
MAF Atlantique motorized doors are certified for fire resistance according to the decree of March 22, 2004, the standards NF S 61-937, EN 16005, accessibility for people with reduced mobility, and benefit from NF277 certification.
What is the added value of the partnership between MAF Atlantique and Record Portes Automatiques?
The partnership makes it possible to offer a comprehensive service across the entire territory including supply, connection, commissioning and maintenance, facilitating the management of automatic fire door projects.
Thematic glossary
Fireproof glass door
Door made of glass panels designed to resist fire and limit the spread of fire.
EI30 Classification
Classification indicating that the door provides flame resistance and thermal insulation for 30 minutes.
Engine
All the equipment that allows a door to open and close automatically.
Safety Actuated Device (SAD)
Equipment providing a safety function such as smoke extraction, opening or closing in case of a fire emergency.
Fire resistance report
Official document attesting to the fire resistance level of a door after regulatory tests.
Maintenance
All maintenance and verification operations aimed at ensuring the proper functioning of motorized security doors.